Swarajya Logo

News Brief

Vizag Gas Leak Mishap: Green Tribunal Says LG Polymers ‘Liable For Loss Of Life’, Another Panel Moots ‘Criminal Prosecution’ Of Management

  • The National Green Tribunal has also said that it should be informed if any statutory clearance were to be given to LG Polymers or if the company plans to resume operations.

M R SubramaniJun 04, 2020, 03:03 PM | Updated 03:03 PM IST
Vizag gas leak incident killed at least eight people. (Picture via Twitter)

Vizag gas leak incident killed at least eight people. (Picture via Twitter)




NGT told the company to spend the interim penalty imposed on it to compensate the victims and restore the environment. The green tribunal rejected LG Polymers petition to review the Rs 50 crore penalty, saying it was justified in taking suo motu cognisance of the mishap, according to an ANI report.

The NGT bench, headed by its chairman Justice Adarsh Kumar Goel, said that the tribunal should be informed if any statutory clearance were to be given to LG Polymers or if the company plans to resume operations.

It also asked the state chief secretary to identify and take action against those responsible for allowing the Vizag plant to operate without statutory clearances within two months and give a report.

The green tribunal said the final compensation LG Polymers would have to pay will be assessed by a committee that includes representatives of the Ministry of Environment and Forests (MoEF), Central Pollution Control Board and National Environmental Engineering Research Institute.

It ordered the setting up of the committee in two weeks time and gave two months for the panel to submit its report. It also ordered the MoEF to set up an expert panel to suggest ways and means to revamp monitoring mechanism to check and prevent violation of environmental norms.

On the other hand, the five-member JMC, headed by Justice Seshasayana Reddy, said the root cause of the mishap was the lack of experience of LG Polymers and LG Chem in monitoring and maintaining full tanks of styrene that were left idle for several weeks, a New Indian Express report said.

The company failed to assess the situation with trained manpower, it said, while recommending prosecution of the management under CrPC.

The JMC said lack of safety response preparedness at the plant affected the early stages of operations and the failure to activate the public siren system led to the loss of lives and many others being affected.


Due to exothermic reaction, the styrene started auto polymerising and led to rapid reaction and heating. As the temperature rose, styrene started vapourising.

Following a rise in pressure inside the tank, five safety valves on the M6 tank rooftop opened and started emitting vapour from around 2.42 am.

No alarm was sounded when vapour leakage occurred and the auto sensor of styrene failed to detect it. Besides, the tank was old in design, compounding the problem.

The situation could have been tackled had the chillers, that kept the tank cool, been functioning, the JMC said, adding that the chillers were switched off in the evening per routine since no chilling was required at night.

On 7 May, styrene gas leak from the Visakhapatnam plant of LG Polymers India, an arm of South Korea’s LG Chem, led to death of 12 people.

Besides, scores of people were hospitalised for breathlessness, nausea and giddiness. Some people living in the plant vicinity were found unconscious while trying to flee from the gas leak.

The mishap has led to demands for shifting the plant from the area, which has turned residential with the expansion of the coastal city.

The LG Polymers plant in Vizag was initially established as Hindustan Polymers in 1961 before McDowell and Co took it over in 1978. LG Chem bought the plant in July 1997 to expand its styrenics business in India.

Join our WhatsApp channel - no spam, only sharp analysis